Please note, this trouble tree is limited to power distribution systems that center around an ignition timer/relay/fuse panel system combo e.g. our Gen I, Gen II, and FasTech power distribution.

1

Is there a fuse in the "Power Timer" position in the fuse block?

Yes
No

Insert a 7.5A fuse and retest.

2

Is there a minimum 12v on the input and output sides of the fuse?

Yes
No

Replace the "Timer Power" fuse (7.5A) and retest.

3

With vehicle ignition on, is there a minimum 12v on the timer's ignition input wire?

Yes
No

Repair the no-voltage condition on ignition input wire and retest.

4

Using the timer instructions for your timer product, is the timer functioning correctly according to the status LED?

Yes
No

The timer is likely faulty. Please contact us for a replacement.

5

Using a multimeter, does the timer have GND on both ground wires and 12v on its input wire?

Yes
No

Repair connections and retest.

6

With ignition turned ON, does the status LED turn solid green and the output wire read 12v?

Yes
No

The timer is likely faulty. Please contact us for a replacement.

7

Using a multimeter, does the relay have both 12v positive and ground on the relay harness?

Yes
No

Repair bad connections on relay connector terminals or wiring or replace the timer.

8

When timer is idle/off and ignition is turned on, does the relay make an audible click, indicating it has energized?

Yes
No

The relay is likely faulty, please contact us for a replacement.

9

With the relay energized, does the load circuit show 12v?

Yes
No

The relay is likely faulty, please contact us for a replacement.

10

Troubleshooting Complete

Timed circuits should be functioning. Please contact us if you need additional support.